RF Power Probe
The new probe RF-SNMP is the evolution of the ANT 131 Precision RF Power Probe. In addition to the precision that has always distinguished the ANT131 probe, RF-SNMP is easy and very quick to install.
It does not require any power input connection, in fact the new RF-SNMP is powered through the LAN cable via POE (Power over Ethernet) and all adjustments are performed via SNMP or web page.
Very high measurement precision and very wide dynamic range make this probe the best choice for transmission systems measurements both at the transmission and at the reception end. RF-SNMP is designed for precision measurement of analog as well as digitally modulated signals. The dynamic range is more than 50dB and its bandwidth is extremely high.
INPUT
Power Range: -40 / +30dBm
Input type: Digital or analog signals (waveform and modulation independent)
Frequency Range: 50 MHz up to 4 GHz
Attenuator: 0 - 31 dB in 0.5 dBm step (software selectable)
Precision: 1 dBm (50 MHz up to 2 GHz)
CONNECTIONS
RF input: BNC male (50 MHz up to 1 GHz)
RF input: SMA male (1 up to 4 GHz)
Ethernet/PoE: RJ45
MISCELLANEOUS
Communication: SNMP protocol, HTTP
Alarms: SNMP Trap with programmable thresholds and polarity
Readings units: dBm, W or KW selectable
Setup: Through Web page and SNMP
Software: Remote upgrade capability
POWER SUPPLY
PoE: PoE 802.3af (class 0).
Power can also be supplied through a 48 Vdc / 0.25 A PoE power injector.
ORDERING CODES
RF-SNMP RF Power Probe Meter 50MHz - 4GHz